Inspection Report of Theatre – Maharashtra Cinemas (Regulation) Rules, 1966

Inspection Report of the Theatre and Other Public Amusement Duly Licensed for Use of Cinema under Maharashtra Cinemas (Regulation) Rules, 1966

Legal Basis: This inspection report format is derived from the Maharashtra Cinemas (Regulation) Rules, 1966 (notified July 12, 1966, with minor amendments up to 2025). These rules govern licensing, structural safety, fire precautions, ventilation, exits, sanitation, and projection facilities for permanent, quasi-permanent, and touring cinemas in Maharashtra.

Quasi-Permanent Cinema Definition: A structure made of steel angles, iron trusses, or other fire-resisting materials (not fully permanent brick/concrete, but more durable than touring/temporary setups).

As of January 2026: No major amendments to core safety/inspection rules since 1966; focus remains on compliance with fire safety, exits, and electrical standards. Licensing involves District Magistrate/Police Commissioner and PWD Executive Engineer.

1Name of Theatre: _________ Talkies at ________ Dist._______.
2Location: Near _____________.
3Whether permit or use permanent: Quasi Permanent.
4Purpose of which used: Public amusement
5Year of Construction:______
6Date of Inspection:____/_____ /________.
7Inspection Notice Fee for the year ______ Date ___/___/____ paid at ______ on ________ Branch ______ Dist._______.
Class Exclusive of Passage details Seats as per 20 Seats Seats as per licence No. of Seats in each Class No. of Seats in each Class
1st Class500.00 sq.ft.80 Seats8080 Seats80 Seats
2nd Class1642.00 sq.ft.280 Seats280280 Seats280 Seats
3rd ClassClass250 Seats250250 Seats250 Seats
Total610610 Seats610 Seats
8Whether the ceiling partition wall in private boxes is of fire resisting materials.:Ceiling of plaster portion of Masonry with plaster.
9If there any other space under the place of the auditorium? If so rented out or used as Godown.:Question does not arise no land is given on rented basis or Godown.
10Is the minimum height between 1st tier Balcony and the floor is of 10 ft.:
11Are the entrance and exit have any access to the public thorough fare what width of this thorough fare?:Yes. Width _____
12And are the No. of exits provided to each class as laid down under this rule?:Yes.
Class No. of Exits required No. of Exits Provided Width of Exit
1st Class1 No.1 No.4'-0"
2nd Class2 No.2 No.4'-0"
3rd Class1 No.1 No.4'-0"
131) Accommodation details at the rate of 9 persons per 100 sq.ft. of the floor area excluding the passage.:1st Class 500.00 sq.ft. 80 Seats
2nd Class 1642.00 sq.ft. 280 Seats
3rd Class 1250.00 sq.ft. 250 Seats
2) Are all seats excluding those in boxes firmly secured to the floors.:Benches and chairs are firmly fixed to the floor.
3) Is the distance of 30 cm left between the back.:Yes.
I) What is the distance width of the screen:--- M.
II) What is the distance of first row from the screen?:--- M.
III) What is the distance of the serial No. II is more than No. I?:--
14I) What is width of the gangway provided at the center and at the gradient:Side Gangway are having 4'-0" width and 5'-0" gangway provided for 2nd class and 3rd class.
II) Are the gangway provided in slope, if in slope what is gradient?:--
III) Are the staircase leading from exits have width of 1.5 metre?:No Steps
15Does the staircase observe the minimum requirement as under.:No Stair cases is provided hence question does not arise.
a) Size of tread and risers?--
b) No of filling with No. of Stages in each filling--
c) Size of landing.--
16In the area of ventilators is 1/5th of total floor area?Yes.
17Are separated latrines urinals provided for Male Female?Yes.
18What are the details of Latrines and urinals?As below.
Floor No. of Seats in Latrines required at Latrines Urinals Urinals
Gents1st 806 Nos.6 Nos.12 Nos.12 Nos.
2nd 280
3rd 250
Total610
19Is the enclosure for the Projectors of sufficient dimension and sufficiently fire proof materials:Being quasi permanent theatre hence question does not arise
I) Are the entrance to this enclosures provided with fire resisting doors which open outside?Yes.
II) What are the no of openings? and are there shuttered provided in the front wall for projection of films?--
III) Are the openings fitted with screen of fire resistance materials complete of opening both from inside and outsideQuestion does not arise.
IV) Is Separate rewinding room is provided? if yes, is it with fire resistant materials?The walls of rewinding room is of masonry and floor of GCI sheets.
20What is the screen width provided? Is it more than 3.85 m?Yes the width is 5.00 m.
21Are the sky lights if provided protected by steel galvanized iron fire sheets.Question does not arise.
22Are lightning conductors provided? Is it more than 3.05 m?Yes.
23Are lightning conductors provided? Is it more than 3.50 m? are lightning conductor provided and in to fare they certified for their workingThe Certificate is enclosed.
24Are storage water tanks provided with capacity for each of them at the rate of 1135 liters per 100 persons each other.Yes, but not in working condition
25I) Is indicator fitted on these tanks and if so, does it show in proper workingYes, not in working condition
II) Is this tank provided with covers for the opening at the top?Yes.
III) How many hydrants that are provided auditorium? what is the dia of the hydrant? How many more than 8 cm? are these hydrants connected to the storage tank by 7.5 cm in dia?1 no's
26Are fire buckets with conical base duly painted with letters provided in sufficient Nos duly filled with water and sand.Yes.
27Are chemical extinguishers sufficient in No of 13.5 liters capacity provided (for set premise only) do they show record of cleaning and recharge at their sides.Yes.
28Does the Operator's projector provided for the following.
1) Two Buckets of sandYes.
2) Two Buckets of waterYes.
3) Two pressure type extinguishersYes.
4) Sponge kept in one of the buckets of water.Yes.
29Are all exits provided with the exit boards and are they well illuminated "EXIT" (For the new premises only)--
30Do the curtains for the doors separate smooth without their trailing on the floorYes.
31Are cloak rooms provided too far as to bear use of them is telephone provided for the care?Yes, Telephone No. (-----) -------------.
32Are No smoking boards in the auditorium?Not provided.
33Are premises outside the theatres are well illuminated during working period of the night period.Yes.
34Are Sufficient No of operators provided auditorium?Yes.
35Is the theatre kept in clean and sanitized conditions?Yes, generally kept clean.