MCQ Hydrology

MCQ Hydrology

Q1. The process of water entering the soil surface is known as:

Q2. The unit of rainfall intensity is typically expressed in:

Q3. A hydrograph represents the variation of which parameter with time?

Q4. The infiltration capacity of soil generally decreases with:

Q5. The stage-discharge relationship in a river is termed as:

Q6. The rainfall excess or effective rainfall is the rainfall available for:

Q7. The runoff coefficient is defined as the ratio of:

Q8. The mass curve of rainfall is a plot of:

Q9. The unit of surface runoff is generally expressed in:

Q10. Which one of the following is a non-recording type rain gauge?

Q11. The time taken by a drop of water to travel from the most distant point in a basin to the outlet is called:

Q12. The area between the rainfall hyetograph and infiltration curve represents:

Q13. Unit hydrograph is based on the assumption of:

Q14. The hyetograph is a plot of:

Q15. The standard non-recording rain gauge used in India is:

Q16. The process by which water moves through the soil to the groundwater is called:

Q17. The Rational Method is used to estimate:

Q18. The term 'base flow' in a hydrograph refers to:

Q19. An isohyet is a line connecting points of:

Q20. The SCS Curve Number method is used to estimate:

Q21. The term 'evapotranspiration' refers to:

Q22. The time from the centroid of rainfall to the peak of the hydrograph is called:

Q23. The Horton’s infiltration equation describes:

Q24. A Thiessen polygon method is used to:

Q25. The term 'interception' in hydrology refers to:

Q26. The Muskingum method is used for:

Q27. The term 'return period' in hydrology refers to:

Q28. The double mass curve technique is used to check:

Q29. The term 'specific yield' in groundwater hydrology refers to:

Q30. The Darcy’s law is used to calculate:

Q31. The term 'aquifer' refers to:

Q32. The process of water vapor turning into liquid water on the ground surface is called:

Q33. The term 'watershed' is synonymous with:

Q34. The Penman-Monteith equation is used to estimate:

Q35. The term 'porosity' in hydrology refers to:

Q36. The term 'hydraulic conductivity' refers to:

Q37. The term 'transmissivity' in groundwater hydrology is defined as:

Q38. The time base of a hydrograph is:

Q39. The term 'specific retention' refers to:

Q40. The intensity-duration-frequency (IDF) curve is used to:

Q41. The term 'field capacity' in hydrology refers to:

Q42. The term 'hydrograph separation' is used to:

Q43. The term 'capillary fringe' refers to:

Q44. The term 'stage' in hydrology refers to:

Q45. The term 'infiltration index' is used to:

Q46. The term 'bank storage' in hydrology refers to:

Q47. The term 'synthetic unit hydrograph' is used to:

Q48. The term 'water table' refers to:

Q49. The term 'evaporation pan' is used to:

Q50. The term 'runoff curve number' is associated with:

Q51. The term 'confined aquifer' refers to:

Q52. The term 'hyetograph' is used to represent:

Q53. The term 'overland flow' refers to:

Q54. The term 'unit hydrograph duration' refers to:

Q55. The term 'specific storage' in groundwater hydrology refers to:

Q56. The term 'depression storage' refers to:

Q57. The term 'streamflow' refers to:

Q58. The term 'isohyetal method' is used to:

Q59. The term 'recession curve' in a hydrograph represents:

Hydraulics / Hydrology

This reference collects commonly used equations and definitions for partially full circular pipes, weirs, open-channel flow, pipe-friction losses, rainfall-runoff estimation, infiltration, flood frequency, evapotranspiration, reservoir storage, groundwater parameters, unit hydrograph theory, flood routing and related hydrologic concepts that appear in the MCQs above. Check the assumptions and units before using any equation for design.

1. Hydraulic Characteristics of a Circular Pipe Flowing Partially Full

Let \(D\) be the internal pipe diameter and \(\theta\) the angle subtended at the pipe centre by the wetted arc. In the equations below, \(\theta\) is expressed in degrees; the sine and cosine functions must use the same angle convention.

\[y=\frac{D}{2}\left(1-\cos\frac{\theta}{2}\right)\]

where \(y\) is the depth of water measured from the invert.

Area of flow

\[A=\frac{\pi D^2}{4}\left(\frac{\theta}{360^\circ}-\frac{\sin\theta}{2\pi}\right)\]

Wetted perimeter

\[P=\frac{\pi D\theta}{360^\circ}\]

Hydraulic radius

\[R=\frac{A}{P}\]

Velocity by Manning's equation

\[V=\frac{1}{n}R^{2/3}S^{1/2}\]

Here \(n\) is Manning's roughness coefficient and \(S\) is the energy slope (dimensionless, m/m). For uniform open-channel flow, the energy slope is commonly approximated by the pipe slope.

Discharge and proportional discharge

\[Q=AV\]

For a full circular pipe flowing under the same Manning \(n\) and slope, let \(A_f=\pi D^2/4\), \(R_f=D/4\), and \(Q_f=A_fV_f\). Then:

\[\frac{Q}{Q_f}=\frac{A}{A_f}\left(\frac{R}{R_f}\right)^{2/3}\]

Equivalently, with \(\theta\) in degrees:

\[\frac{Q}{Q_f}=\left(\frac{\theta}{360^\circ}-\frac{\sin\theta}{2\pi}\right)\left(1-\frac{180\sin\theta}{\pi\theta}\right)^{2/3}\]

For a detailed derivation, see Hydraulic Characteristics of a Circular Pipe.

Use carefully: At \(\theta=360^\circ\), use the full-pipe limit directly to avoid numerical division by zero in intermediate expressions. A partially full gravity pipe is not necessarily operating under the same conditions as a pressurised full pipe.

2. Broad-Crested Weir

A broad-crested weir has a relatively long crest in the direction of flow. A commonly used general form is:

\[Q=C\,L\,H^{3/2}\]

where \(Q\) is discharge (m³/s), \(L\) is effective crest width (m), \(H\) is upstream total head above the crest (m), and \(C\) is a coefficient whose value and units depend on the adopted equation and flow conditions.

The coefficient is not universal. Select it from an applicable standard or calibration for the actual weir geometry, approach velocity and flow regime. Do not apply a coefficient formula outside its stated range.

3. Sharp-Crested Weirs

3.1 Rectangular sharp-crested weir

For a fully contracted rectangular sharp-crested weir, the Francis-type metric equation is often written approximately as:

\[Q=1.84\,(L-0.1\,n_c\,H)\,H^{3/2}\]

where \(Q\) is in m³/s, \(L\) and \(H\) are in metres, and \(n_c\) is the number of end contractions (0 for a suppressed weir; commonly 2 for a fully contracted rectangular weir). This empirical form is valid only under its associated experimental assumptions; use the governing standard for design or measurement.

3.2 V-notch (triangular) sharp-crested weir

\[Q=\frac{8}{15}C_d\sqrt{2g}\tan\left(\frac{\theta}{2}\right)H^{5/2}\]

where \(C_d\) is the discharge coefficient, \(g\approx9.81\text{ m/s}^2\), \(\theta\) is the included notch angle, and \(H\) is the head above the notch apex. Use a calibrated coefficient and ensure the approach flow and nappe conditions meet the selected method's requirements.

3.3 Trapezoidal notch

A trapezoidal notch combines rectangular and triangular portions. Its discharge should be calculated using a recognised equation for the particular notch geometry and coefficient convention. The coefficient expression sometimes reproduced as \(\frac{2}{3}(1+\frac{2h}{b})(1-\frac{h}{H})^{3/2}\) is not a generally applicable discharge coefficient and is therefore not presented here as a universal design equation.

4. Chezy Formula

\[V=C\sqrt{RS}\]

\(V\) = mean velocity (m/s); \(C\) = Chezy coefficient (units depend on the unit system, commonly m\(^{1/2}\)/s in SI); \(R=A/P\) = hydraulic radius (m); and \(S\) = energy slope (m/m).

The Chezy coefficient must be selected or calibrated for the channel and flow conditions. It is not dimensionless in a consistent dimensional analysis.

5. Darcy–Weisbach Friction Head Loss

\[h_f=f_D\frac{L}{D}\frac{V^2}{2g}\]

\(h_f\) = friction head loss (m); \(f_D\) = Darcy friction factor (dimensionless); \(L\) = pipe length (m); \(D\) = internal pipe diameter (m); \(V\) = mean velocity (m/s); and \(g\approx9.81\text{ m/s}^2\).

Use the Darcy friction factor in this equation. The Fanning friction factor is one-quarter of the Darcy factor. Minor losses from bends, valves, entrances and exits are separate and may be added as \(h_m=K V^2/(2g)\) where appropriate.

6. Manning's Formula for Open Channels

\[V=\frac{1}{n}R^{2/3}S^{1/2}\]

\(V\) = mean velocity (m/s); \(n\) = Manning roughness coefficient; \(R\) = hydraulic radius (m); and \(S\) = energy slope (m/m). Discharge is \(Q=AV\), where \(A\) is the flow area (m²).

7. Runoff Coefficient Method (Rational Formula)

\[Q=0.00278\,C\,I\,A\]

For \(Q\) in m³/s, rainfall intensity \(I\) in mm/h and catchment area \(A\) in hectares, the conversion factor 0.00278 is required. \(C\) is the dimensionless runoff coefficient.

The Rational Method is generally used for small catchments where its assumptions are appropriate. Choose rainfall intensity for a duration related to the catchment time of concentration and the required design return period.

8. Time of Concentration — Kirpich Equation

\[T_c=0.01947\,L^{0.77}S^{-0.385}\]

This version estimates \(T_c\) in minutes when \(L\) is the channel length in metres and \(S\) is the dimensionless average slope (m/m). The equation is empirical and should be used only within an appropriate catchment range.

9. Rainfall Intensity–Duration–Frequency (IDF)

\[I=\frac{K\,T_r^n}{(t+b)^m}\]

\(I\) = rainfall intensity; \(T_r\) = return period (years); \(t\) = storm duration; and \(K,n,b,m\) = locally fitted constants. The units for \(t\), \(I\), and the constants must match the IDF model from which they were derived. This is a general model form, not a universal set of constants.

10. Infiltration Rate — Horton's Equation

\[f(t)=f_c+(f_0-f_c)e^{-kt}\]

\(f(t)\) = infiltration rate at time \(t\); \(f_0\) = initial infiltration rate; \(f_c\) = final constant infiltration rate; and \(k\) = decay constant. If \(t\) is in hours, \(k\) must be in h\(^{-1}\); use consistent units for all infiltration rates.

11. SCS Curve Number Method — Direct Runoff

Potential maximum retention after runoff begins:

\[S=\frac{25400}{CN}-254\]

Here \(S\) is in millimetres and \(CN\) is the dimensionless curve number (for the metric form).

With the conventional initial-abstraction assumption \(I_a=0.2S\), direct runoff depth is:

\[Q_d=\begin{cases}\dfrac{(P-0.2S)^2}{P+0.8S},&P>0.2S\\[6pt]0,&P\leq0.2S\end{cases}\]

\(P\) = storm rainfall depth (mm); \(Q_d\) = direct runoff depth (mm). The original formula is incomplete unless the condition \(P>I_a\) is stated; otherwise runoff is zero.

12. Unit Hydrograph Peak Discharge

\[Q_p=\frac{2.78\,A}{T_r}\]

This expression appeared in the source material, with \(Q_p\) in m³/s, \(A\) in km² and \(T_r\) in hours. Verify the derivation before use: the constant depends on the assumed hydrograph shape and the definition of \(T_r\) (such as time to peak or effective rainfall duration). It is not a universal unit-hydrograph equation. Use the peak formula corresponding to the adopted unit-hydrograph method and duration.

13. Flood Frequency Analysis — Gumbel Form

\[X_T=\bar X+K_T\sigma\]

\(X_T\) = estimated flood magnitude for return period \(T\); \(\bar X\) = sample mean; \(\sigma\) = sample standard deviation; and \(K_T\) = frequency factor for the selected distribution and return period. For a Gumbel distribution, calculate \(K_T\) using the relevant sample size and frequency-factor procedure; it is not a fixed constant.

14. Probability of Exceedance — Plotting Position

\[P_e=\frac{m}{N+1}\times100\%\]

\(m\) = rank of the event in the ordered series and \(N\) = number of observations. State the ranking convention used. For annual maximum floods sorted from largest to smallest, this plotting position estimates exceedance probability; the corresponding return period is often estimated as \(T\approx1/(P_e/100)\) years, subject to the assumptions of the analysis.

15. Evapotranspiration — Blaney–Criddle Method

\[ET=p(0.46T+8)\]

This is a simplified form of the Blaney–Criddle relationship. \(T\) is mean daily temperature in °C and \(p\) is the percentage fraction of annual daytime hours for the period, expressed according to the convention required by the selected version of the method. The result and time period depend on the method's units and adjustments. For crop-water design, use the applicable calibrated/adjusted method rather than treating this simplified equation as universally sufficient.

16. Reservoir Storage — Prismoidal Formula

\[V=\frac{h}{3}(A_1+4A_m+A_2)\]

\(V\) = volume between sections (m³); \(h\) = vertical interval between the end sections (m); \(A_1\) and \(A_2\) = end areas (m²); and \(A_m\) = area at the midpoint (m²). This formula assumes the midpoint area is available and the area variation is suitably represented by the prismoidal rule.

17. Darcy’s Law (Groundwater Flow)

Darcy’s law relates the discharge of groundwater through a porous medium to the hydraulic gradient:

\[Q=-KA\frac{dh}{dl}\]

or in terms of specific discharge (Darcy velocity):

\[v=-K\frac{dh}{dl}\]

where \(Q\) is volumetric discharge (m³/s), \(K\) is hydraulic conductivity (m/s), \(A\) is cross-sectional area perpendicular to flow (m²), and \(dh/dl\) is the hydraulic gradient (dimensionless). The negative sign indicates flow in the direction of decreasing head. This is the fundamental equation for calculating groundwater flow through aquifers (related to MCQ on Darcy’s law).

18. Key Groundwater Parameters

Porosity (\(n\))

\[n=\frac{V_v}{V_t}\]

where \(V_v\) is volume of voids and \(V_t\) is total volume. Porosity is the fraction of void space that can hold water.

Specific Yield (\(S_y\))

\[S_y=\frac{V_d}{V_t}\]

\(V_d\) is the volume of water drained by gravity from a saturated volume \(V_t\) of aquifer. Specific yield is the drainable porosity of an unconfined aquifer.

Specific Retention (\(S_r\))

\[S_r=n-S_y\]

Specific retention is the fraction of water retained against gravity by capillary forces.

Hydraulic Conductivity (\(K\))

The ease with which water moves through a porous medium. Units are length/time (m/s or m/day). Related to permeability and fluid properties.

Transmissivity (\(T\))

\[T=Kb\]

where \(b\) is the saturated thickness of the aquifer (m). Transmissivity is the rate at which water is transmitted through a unit width of the aquifer under a unit hydraulic gradient (m²/s).

Specific Storage (\(S_s\))

\[S_s=\rho g(\alpha+n\beta)\]

Volume of water released from storage per unit volume of aquifer per unit decline in head. \(\alpha\) is aquifer compressibility and \(\beta\) is water compressibility.

Storativity / Storage Coefficient (\(S\))

\[S=S_s b\quad\text{(confined)}\qquad S\approx S_y\quad\text{(unconfined)}\]

Volume of water released per unit surface area of aquifer per unit decline in head (dimensionless).

19. Aquifer Types

Unconfined aquifer: water table forms the upper surface; open to the atmosphere. Recharge occurs mainly from above.

Confined aquifer: bounded above and below by impermeable (or low-permeability) layers (aquitards/aquicludes). Water is under pressure greater than atmospheric; a well penetrating a confined aquifer may flow freely (artesian) if the potentiometric surface is above ground level.

Water table: the surface at which pore-water pressure equals atmospheric pressure; the boundary between saturated and unsaturated zones.

Capillary fringe: the zone immediately above the water table where water is held by capillary forces against gravity.

20. Unit Hydrograph Theory

A unit hydrograph (UH) is the direct-runoff hydrograph resulting from 1 unit (usually 1 cm or 1 mm) of excess rainfall generated uniformly over the catchment at a constant rate for a specified duration \(D\).

Key assumptions:

  • Linear response of the catchment (principle of superposition and proportionality).
  • Time-invariance (same excess rainfall produces the same UH regardless of when it occurs).
  • Uniform spatial distribution of excess rainfall.

The duration of the unit hydrograph is the duration of the effective (excess) rainfall that produces it. Synthetic unit hydrographs are derived for ungauged catchments using empirical relations based on catchment characteristics.

Peak discharge of a unit hydrograph is often estimated by formulae of the general form:

\[Q_p=\frac{C\,A}{t_p}\]

where \(C\) is a coefficient depending on units and assumed hydrograph shape, \(A\) is catchment area, and \(t_p\) is time to peak. Always verify the constant against the specific method being used.

21. Hydrograph Components and Timing

Base flow: the sustained portion of streamflow contributed by groundwater discharge into the channel.

Direct runoff (or surface runoff + interflow): the rapid response portion of the hydrograph resulting from a rainfall event after initial losses.

Time of concentration (\(T_c\)): the time required for a drop of water to travel from the most distant point in the catchment to the outlet.

Lag time: the time from the centroid of excess rainfall to the peak of the hydrograph (or sometimes to the centroid of the runoff hydrograph).

Time base: the total duration of direct runoff on the hydrograph.

Recession curve: the falling limb of the hydrograph after the peak, representing depletion of channel and subsurface storage.

Hydrograph separation techniques are used to divide a total streamflow hydrograph into base-flow and direct-runoff components.

22. Muskingum Flood Routing

The Muskingum method is a hydrologic channel-routing technique based on the storage equation:

\[S=K\bigl[xI+(1-x)O\bigr]\]

where \(S\) is channel storage, \(I\) is inflow, \(O\) is outflow, \(K\) is a storage-time constant (approximately equal to travel time), and \(x\) is a weighting factor (0 ≤ \(x\) ≤ 0.5) that accounts for the relative importance of inflow and outflow on storage. The routing equation is solved in finite-difference form over successive time steps. It is widely used for flood routing in rivers and channels.

23. Penman–Monteith Evapotranspiration

The FAO Penman–Monteith equation is the standard method for estimating reference crop evapotranspiration (\(ET_0\)):

\[ET_0=\frac{0.408\Delta(R_n-G)+\gamma\frac{900}{T+273}u_2(e_s-e_a)}{\Delta+\gamma(1+0.34u_2)}\]

where \(R_n\) is net radiation, \(G\) is soil heat flux, \(T\) is air temperature (°C), \(u_2\) is wind speed at 2 m height, \(e_s-e_a\) is vapour-pressure deficit, \(\Delta\) is the slope of the saturation vapour-pressure curve, and \(\gamma\) is the psychrometric constant. It combines energy-balance and aerodynamic terms and is preferred for crop-water requirement calculations when the necessary meteorological data are available.

24. Rainfall Measurement and Averaging Methods

Non-recording (manual) gauges: Symons gauge (standard in India) measures total rainfall depth over a period without continuous recording.

Recording gauges: tipping-bucket, weighing-bucket and float-type gauges produce a continuous record of rainfall intensity or cumulative depth.

Thiessen polygon method: assigns areal weights to each rain gauge by constructing perpendicular bisectors between stations; average rainfall is the weighted mean of station depths.

Isohyetal method: draws isohyets (lines of equal rainfall) and computes the area-weighted average rainfall from the isohyetal map. Generally more accurate when topographic effects are significant.

Double-mass curve: cumulative rainfall at a station is plotted against the cumulative average of surrounding stations to detect and correct for inconsistencies in the rainfall record.

25. Infiltration Concepts

Infiltration: the process of water entering the soil surface.

Percolation: the downward movement of water through the soil profile toward the groundwater table.

Infiltration capacity: the maximum rate at which soil can absorb water; it typically decreases with time as the soil becomes wetter (Horton’s equation models this exponential decay).

Infiltration index (\(\phi\)-index or \(W\)-index): the average infiltration rate during a storm such that the volume of rainfall in excess of the index equals the observed direct-runoff volume.

Initial losses: interception by vegetation + depression storage + infiltration before runoff begins. Excess (effective) rainfall is the rainfall remaining after these losses and is the rainfall that produces surface runoff.

26. Runoff Coefficient and Rational Method Notes

The runoff coefficient \(C\) is defined as:

\[C=\frac{\text{Runoff volume (or peak)}}{\text{Rainfall volume (or intensity)}}\quad(0\le C\le 1)\]

It accounts for losses due to infiltration, interception, depression storage and evaporation. In the Rational Method the peak discharge is estimated as \(Q=CiA\) (with appropriate unit conversion). The method is intended for small catchments where the assumptions of uniform rainfall intensity over the time of concentration are reasonable.

27. Rating Curve (Stage–Discharge Relationship)

A rating curve is the empirical relationship between water-surface elevation (stage) and discharge at a gauging station. Once established (and periodically checked), it allows continuous discharge estimation from continuous stage records. The relationship can shift due to scour, deposition, weed growth or backwater effects, so rating curves require regular verification.

28. Return Period and Exceedance Probability

The return period \(T\) of an event is the average number of years between occurrences of an event of equal or greater magnitude:

\[T=\frac{1}{P}\]

where \(P\) is the annual exceedance probability. A 100-year flood has an annual exceedance probability of 0.01 (1 %). Return period is a statistical concept, not a guarantee that the event will occur exactly once every \(T\) years.

Important Engineering Checks

  • Keep units consistent throughout each calculation.
  • Confirm whether angles are in degrees or radians; do not mix conventions.
  • Use coefficients from an applicable standard, published method or site calibration.
  • Distinguish head above a weir crest from upstream water depth and approach velocity head.
  • For design submissions, record assumptions, catchment data, return period, roughness values and the source of coefficients.

This page is a technical reference, not a substitute for project-specific hydraulic design, applicable standards or independent checking.