PEB Portal Frame Studio
Create a clear 2D transverse portal-frame geometry starter for a pre-engineered building concept. Adjust the roof form and built-up member depth schedule, review geometry checks, export a STAAD.Pro .STD starter, and use the engineering guide to complete the actual building model.
1 · Portal-frame geometry
This file generates one transverse 2D frame in the global X–Y plane. It is not a complete 3D building model.
2 · Geometry and section audit
Checks input ranges, ridge location, member connectivity and taper schedule continuity. These are not capacity checks.
3 · STAAD.Pro preview
No model generated yet.
How to use this PEB tool
The tool creates one 2D transverse frame: two columns connected to one or two rafters. Intermediate nodes divide each member into shorter segments so a built-up section depth can vary in a piecewise schedule. The exported file is geometry only. It does not design the frame or represent the full building system.
1. Choose the roof form
- Symmetric gable: both eaves are at the same elevation and the ridge is at midspan.
- Asymmetric gable: one ridge lies at the entered transverse coordinate; the roof rises from the left eave to that ridge and falls to the right eave.
- Single slope: the roof line runs from the left eave elevation to the entered high-end elevation.
The shape is a straight-line idealization. It does not add a haunch plate, knee stiffener, ridge splice, connection geometry, camber or fabrication allowance.
2. Read the section schedule correctly
Column and rafter depths are overall section-depth targets at segment ends. Flange width, flange thickness and web thickness are recorded as schedule metadata. The output does not assign a fabricated I-section property because a safe STAAD property command must match the installed release and the exact built-up section conventions. Assign the actual section property in STAAD.Pro and confirm that depth, flange orientation, taper interpolation and local axes are represented as intended.
Segmenting a taper into prismatic pieces is a modeling approximation. Select the segment count by checking convergence of relevant actions/deflections and compare against a continuous tapered-member or shell model when local behavior matters.
3. Complete the 3D building
A real PEB needs longitudinal stability as well as transverse portal frames. Build the frame lines at the actual bay spacing in a 3D model, then add roof and wall purlins/girts, eave struts, flange restraints, roof/wall bracing, end-wall framing, sag rods, sheeting restraints, and crane/other equipment support where applicable. Verify diaphragm assumptions and load transfer at every interface. This 2D file includes none of those systems.
4. Define supports and loads from the project
Determine base plate/anchor-bolt and foundation stiffness/restraint assumptions with the foundation engineer. Evaluate dead load, roof imposed load, wind pressure and suction (including internal pressure and edge/corner zones), snow where relevant, seismic action, temperature, crane loads, collateral/MEP loads, erection loads and combinations. Wind coefficients depend on geometry, openings, terrain, topography and internal pressure; the tool intentionally does not insert generic wind or roof-live loads.
5. Analysis, design and review
- Use the adopted editions/amendments of IS 800, IS 875 and applicable seismic provisions.
- Check global stability, second-order effects, imperfections, sway, buckling lengths, lateral-torsional buckling and restraint assumptions.
- Check member section classification, local slenderness, web/flange yielding and buckling, shear, bending/axial interaction, serviceability drift/deflection and ponding where relevant.
- Design connections, splices, base plates, anchor rods, purlins/girts and bracing separately; include erection and construction-stage stability.
- Review analysis equilibrium, reactions, load paths, local axes, deformed shapes and mesh/segment sensitivity independently.
Codes, amendments and technical papers
Source check: 28 October 2026. Confirm the standard edition, amendments, contract documents and authority requirements applicable to the project.
Bureau of Indian Standards
- IS 800:2007, General Construction in Steel (Third Revision), BIS lists Amendment 1 (2012) and Amendment 2 (2024). Check the BIS detail record and obtain official text/amendments: BIS standard details.
- IS 875 (Part 3):2015, Wind Loads (Third Revision): BIS records review in 2025 and amendments from 2016 and 2020. This is the central reference for building wind actions; calculate external and internal pressures from project geometry and site data. BIS record and amendment list.
- IS 875 (Part 2):1987, Imposed Loads: roof imposed load must follow occupancy, roof slope/access and the adopted code provisions; the sample value in the pasted tool was not justified. BIS detail record.
- IS 875 (Part 1):2026, Dead Loads: BIS currently lists the 1987 edition as withdrawn on 20 September 2026 and superseded by the 2026 edition. Confirm transition/effective applicability and use the current official text for material unit weights. BIS record showing supersession.
- IS 875 (Part 4):2021 Snow Loads and Part 5:1987 Special Loads and Load Combinations: check snow relevance and special actions/combinations for the site and use. BIS referenced standards listing.
- IS 1893 (Part 4):2024, Industrial Structures and Stack-like Structures (Second Revision): relevant seismic standard for industrial facilities; use with applicable general seismic provisions and project criteria. BIS-hosted standard document.
- IS 801:1975 may apply to cold-formed light-gauge purlins/girts; verify applicability, amendments and the specified product system separately.
STAAD.Pro documentation
- Use the Bentley manual for the installed release to verify tapered members, section properties, releases, supports, loads, code parameters and analysis: STAAD.Pro manual.
Technical papers informing the guide
- McKinstray, R. et al. (2016), “Comparison of optimal designs of steel portal frames including topological asymmetry considering rolled, fabricated and tapered sections,” Engineering Structures 111, 505–524. Highlights that configuration and serviceability constraints influence optimal frame weight. DOI: 10.1016/j.engstruct.2015.12.028.
- Li, J.-J. & Li, G.-Q. (2002), “Large-Scale Testing of Steel Portal Frames Comprising Tapered Beams and Columns,” Advances in Structural Engineering 5(4), 259–269. Reports full-scale tests of tapered frames under vertical and combined vertical/horizontal loading. DOI: 10.1260/136943302320974626.
- Couto, C., Oliveira, D. & Vila Real, P. (2022), “A Study on the Capacity of Steel Portal Frames using Shell Finite Elements,” ce/papers 5(4), 1017–1026. Discusses capacity modeling of tapered/slender portal frames. DOI: 10.1002/cepa.1846.
- Silva, F. T. & Pimentel, R. L. (2023), “Optimization of Steel Portal Frames under a Parametric Structural Design Framework,” Practice Periodical on Structural Design and Construction 28(1). Includes 3D model parameterization, stability and serviceability in the design process. DOI: 10.1061/(ASCE)SC.1943-5576.0000748.
Research papers explain modeling and verification methods; they do not replace Indian Standards or constitute project design advice.
0 Comments
If you have any doubts, suggestions , corrections etc. let me know