MCQ Environmental Engineering
Topics: Water supply & treatment · Wastewater · Air pollution · Municipal solid waste · Noise pollution
Q1. Per capita water demand for domestic use in India (typical design value) is of the order of:
Q2. The most important parameter for bacteriological quality of drinking water is:
Q3. Residual chlorine in treated water at the consumer end is typically maintained around:
Q4. Hardness in water is mainly due to:
Q5. The correct sequence of conventional surface-water treatment is:
Q6. Alum is added in water treatment primarily as a:
Q7. Rapid sand filters are cleaned by:
Q8. Chlorination is mainly done for:
Q9. Average domestic sewage generation is often taken as about:
Q10. BOD₅ represents:
Q11. COD is generally:
Q12. Total solids in wastewater include:
Q13. Primary treatment of sewage mainly removes:
Q14. Activated sludge process is a type of:
Q15. Trickling filters are:
Q16. The purpose of a secondary clarifier in ASP is to:
Q17. Sludge digestion (anaerobic) primarily aims to:
Q18. Tertiary treatment is used when:
Q19. The primary gaseous pollutant from combustion of sulphur-bearing fuel is:
Q20. Photochemical smog is associated with:
Q21. A stable atmosphere (inversion) tends to:
Q22. Electrostatic precipitators are used to control:
Q23. National ambient air quality standards in India are notified for pollutants including:
Q24. Typical composition of municipal solid waste in Indian cities has a high fraction of:
Q25. The preferred hierarchy in solid waste management is:
Q26. Sanitary landfills differ from open dumps mainly by:
Q27. Composting of MSW is a method of:
Q28. Sound pressure level is commonly expressed in:
Q29. A-weighting (dB(A)) is used because:
Q30. Permissible ambient noise limit for residential areas at night in India (typical CPCB) is about:
Environmental Engineering – Theory & Key Points
Demand components: domestic, industrial, commercial, public use, fire demand, losses. Design often uses 135–200 lpcd for domestic supply (CPHEEO/IS guidance; varies with city size).
Drinking water standards (illustrative BIS/WHO themes): turbidity, colour, pH, hardness, iron, fluoride, nitrate, residual chlorine, and bacteriological criteria (coliforms/E. coli). Standards set acceptable/permissible limits for health and acceptability.
Typical train:
- Screening / pre-treatment – remove debris.
- Aeration (if needed) – strip gases, oxidise Fe/Mn.
- Coagulation–flocculation – alum/ferric salts + mixing; colloidal destabilisation and floc growth.
- Sedimentation – settle flocs.
- Filtration – rapid sand / dual media; polish residual turbidity.
- Disinfection – chlorine, chloramines, UV, ozone; maintain residual in distribution.
Softening (lime–soda or ion exchange), adsorption (GAC), membrane processes and fluoridation/defluoridation are additional processes as required.
Distribution: service reservoirs, pumping, grid/branched/ring networks; maintain pressure and residual disinfectant; minimise leakage and contamination.
Sewage quantity ≈ 70–80% of water supplied (plus infiltration/inflow in sewers).
Key parameters:
- BOD₅ – oxygen used by microbes over 5 days at 20°C; measure of biodegradable organics.
- COD – chemical oxygen demand; includes non-biodegradable organics; COD > BOD.
- TSS / VSS – suspended solids; settleable solids measured in Imhoff cone.
- Nutrients (N, P), pathogens, pH, oil & grease, heavy metals (industrial contribution).
Primary: screens → grit chamber → primary sedimentation. Removes settleable SS and floating matter; BOD reduction modest (~25–35%).
Secondary (biological):
- Activated sludge process (ASP) – aerobic suspended growth; aeration tank + secondary clarifier; return activated sludge (RAS).
- Trickling filter / biofilter – aerobic attached growth.
- Oxidation ponds / stabilisation ponds – natural systems.
- UASB and other anaerobic processes for medium–high strength wastes.
Tertiary / advanced: nutrient removal (N, P), filtration, disinfection, membranes – for reuse or sensitive receiving waters.
Sludge: thickening → digestion (anaerobic/aerobic) → dewatering → disposal/reuse (compost, controlled land application) subject to standards.
Effluent standards: prescribed BOD, TSS, pH, residual Cl₂, nutrients, etc. for discharge to inland surface waters, public sewers, land irrigation or marine outfall (CPCB/SPCB).
Primary pollutants: SO₂, NOx, CO, PM (PM₁₀, PM₂.₅), VOCs, Pb – emitted directly.
Secondary: ozone, PAN, sulphates/nitrates – form in atmosphere (e.g. photochemical smog from NOx + VOCs + sunlight).
Sources: vehicles, industry, power plants, biomass burning, construction, natural (dust, volcanoes).
Impacts: health (respiratory, cardiovascular), visibility, acid rain, crop damage, climate forcing.
Meteorology: wind speed/direction, mixing height, stability and inversions control dispersion. Stable conditions and inversions trap pollutants.
Control:
- Particulates – cyclones, bag filters, ESPs, scrubbers.
- Gases – absorption, adsorption, catalytic converters, FGD (for SO₂), SCR/SNCR (for NOx).
Standards: National Ambient Air Quality Standards (NAAQS) for ambient air; emission standards for stacks and vehicles.
Characteristics: composition (organics, paper, plastics, glass, metal, inert), moisture, calorific value, density – vary by income, season, culture.
Generation, collection & transport: per-capita generation rates; storage; primary/secondary collection; transfer stations; haul to processing/disposal.
Management hierarchy: reduce → reuse → recycle → energy recovery → treat → dispose.
Engineered systems:
- Material recovery facilities, composting, biomethanation.
- Waste-to-energy (where calorific value and emissions control allow).
- Sanitary landfill – liner, leachate collection, gas management, daily cover, closure and post-closure care (not open dumping).
Sound level is measured in decibels (dB); environmental noise usually reported as dB(A) (A-weighted).
$$ L_p = 20\log_{10}\frac{p}{p_0}\ \text{dB},\quad p_0 = 20\ \mu\mathrm{Pa} $$
Impacts: hearing impairment, sleep disturbance, stress, reduced productivity, interference with communication.
Limits (illustrative CPCB ambient standards): residential 55 dB(A) day / 45 dB(A) night; commercial and industrial zones higher; silence zones stricter.
Control: source control (quieter machinery, maintenance), path control (barriers, enclosures, distance), receiver protection (PPE), land-use planning and timing restrictions.